<span id="zfqta"><sup id="zfqta"></sup></span>

    1. <span id="zfqta"></span>
    2. <span id="zfqta"><output id="zfqta"></output></span>

        頂部鏈接&語言切換

        Time of issue:2021-09-16 17:43:45
        imgboxbg

        Products

        Creatinine test strips (Dry chemical method)
        1/1
        Number of views:
        1000
        Creatinine Test Strips (Dry chemical method) is suitable for quantitative determination of creatinine concentration in whole blood or serum in vitro. Creatinine is the metabolic end product of creatine phosphate in human muscles, which is mainly cleared through glomerular fifiltration. Under normal circumstances, the serum creatinine level in human body remains basically stable. When the kidneys are damaged, the normal excretion of creatinine in body is blocked, and serum creatinine levels are elevated. Therefore, serum creatinine concentration can reflflect the glomerular fifiltration rate. It is clinically used as a routine item for the monitoring and analyzing of renal function.
        Number of views:
        1000
        Product serial number
        Quantity
        -
        +
        1
        Product Description
        產品詳細右側內容:

        Creatinine Test Strips (Dry chemical method) is suitable for quantitative determination of creatinine concentration in whole blood or serum in vitro.

        Creatinine is the metabolic end product of creatine phosphate in human muscles, which is mainly cleared through glomerular fifiltration. Under normal circumstances, the serum creatinine level in human body remains basically stable. When the kidneys are damaged, the normal excretion of creatinine in body is blocked, and serum creatinine levels are elevated. Therefore, serum creatinine concentration can reflflect the glomerular fifiltration rate. It is clinically used as a routine item for the monitoring and analyzing of renal function.

        Intended Use

        Creatinine Test Strips (Dry chemical method) is suitable for quantitative determination of creatinine concentration in whole blood or serum in vitro.

        Creatinine is the metabolic end product of creatine phosphate in human muscles, which is mainly cleared through glomerular fifiltration. Under normal circumstances, the serum creatinine level in human body remains basically stable. When the kidneys are damaged, the normal excretion of creatinine in body is blocked, and serum creatinine levels are elevated. Therefore, serum creatinine concentration can reflflect the glomerular fifiltration rate. It is clinically used as a routine item for the monitoring and analyzing of renal function. At present, there are enzymatic methods and chemiluminescence methods commonly used to detect creatinine content in blood samples.

         

        Product Information

        Production name

        Test samples

        Specifications

        Creatinine test strips (Dry chemical method)

        whole blood or serum samples

        15 tests/ kit, 50 tests/ kit

         

        Storage Conditions and Expiry Date

        All reagents are ready to use as supplied.

        For Aluminum foil bag package: unopened reagent kits are stable at 4°C ~30°C for 18 months tentatively. Please use the test strip within 1 hour once the foil bag is open.

        For cylinder package: unopened reagent kits are stable at 4°C ~30°C for 18 months tentatively.the test strips in cylinder are stable at 4°C ~30°C for 30 days tentatively once the cylinder package is opened.

         

        Test Procedure

        1. Read the instruction carefully before use.

        2. Insert the IC card that matches the lot number on the test strips.

        3. Take out the test strip from the aluminum foil bag or drying cylinder, insert it into the analyzer until the end cannot go any further.

        4. When ‘ADD SAMPLE’ appears on the display, use a capillary blood collector or pipet to apply 20μL of whole blood or serum sample to the test strip sample application window.

        5. In about 4 minutes, the results will appear on the display automatically on the analyzer.

        6. Calibrator and quality control instructions: The test strip adopts IC card calibration mode, and the analyzer automatically reads batch-specifific calibration data from the IC card without user calibration.

        7. Take out and discard the test strip. The test strip is for one-time use only. Do not use it again.

        We could not find any corresponding parameters, please add them to the properties table
        Previous
        Next

        底部版權信息

        Time of issue:2021-06-08 11:15:00

        Copyright©2021 Lumigenex (Suzhou) Co., Ltd. All Rights Reserved. Website construction: www.300.cn

        底部備案信息

        Time of issue:2021-09-17 09:20:58

        分享按鈕

        Time of issue:2021-09-17 11:04:49

           

        久久精品人人做人人综合,青青热久免费精品视频在大全,国产高潮刺激叫喊视频,国内大量揄拍人妻在线视频

          <span id="zfqta"><sup id="zfqta"></sup></span>

          1. <span id="zfqta"></span>
          2. <span id="zfqta"><output id="zfqta"></output></span>